One, the regulation of vertical:
1, let the pneumatic motor below the quick change joint work with desktop or the workpiece surface contact, determine the quick change joint and vertical, (quick change joint work with desktop gapless), and then the locking vertical plate or universal heads of 4 screws.
2, the air tube is connected to the triple parts and motor.
Two, a pneumatic motor operation
1, a pneumatic motor press the front end of the "trigger" motor is transferred; tapping, while the pressure back "reverse button" is a pneumatic motor reversal; retreat
Out of.
2, parallel arm can easily move to the tapping position, not to be pressed down, let the tap as screw like, without resistance to import.
Three, air requirements:
1, the intake pipe must be 3/8 inch or more than 10mm, the length of not more than 10M.
2, the set pressure in 3-6KG.
3, adjust the air FRL the oil dripping speed for each minute 1 to 2 drops of oil drops too fast, if the motor is because of too much oil in the exhaust and become wet
Answer answer.
4, every day to check the oil level in the oil, the oil and oil dripping speed.
5, please use special tools (pneumatic oil viscosity of about 30); CASROL QWS, SHELL TELIUS 32, MOBIL OIL DTE 24, BP ENERGOL
HLP 32
Four, the adjustment of torsion torque:
1, usually torsion collet torque at the factory that has been set, but the use of a period of time in the material is strong attack or, must adjust,
The set torque.
2, torsion collet housing with 2 holes, allowed to do half a groove torque adjustment, the adjustment in the M3 below the torque control is very important.
3, using a slotted screwdriver to buckle, with 2 round pliers placement torque force adjusting ring on the inner, clockwise rotation increased torque, counterclockwise rotation
Reduction of torsion.
4, after adjustment, the retaining ring is inserted into the keyhole collet housing, torque is not changed.
5, the torque is to ensure the high precision collet thread, so the torque collet not random, litter, broke, so as not to affect the tapping accuracy.
6, when the pneumatic motor does not turn when, in general is not strong enough, please check the pressure is adjusted to 6-8KG.
7, when the pneumatic motor rotor, and torsion collet slip, there may be a material is too hard or material viscosity, please put the torque torque increase.
8, in the tapping process, such as a broken tap phenomenon, check whether the motor is vertical to the workpiece, or torque. Torque is too large, please the torque.
Torque control.
Five, the machine must be operated by a special person to keep: fixed personnel, such as storage, machine sound, should immediately stop using, and check processing, until the normal. Remember not to open the motor. Because the pneumatic motor brand products, the world is very precise, the manufacturers in order to prevent imitation, in general, not the brand of professional personnel, open the motor can not restore. Privately apart motor unable to repair is not within the scope of the warranty.